| Model |
GTH-150 |
GTH-225 |
GTH-408 |
GTH-800 |
| Internal Dim. W × H × D (cm) |
50×60×50 |
50×75×60 |
60×85×80 |
100×100×80 |
| External Dim. W × H × D (cm) |
97×145×100 |
95×160×110 |
105×175×130 |
145×210×130 |
| * Temp. & Humi. Range |
0℃; -20℃ ; -40℃ ; -60℃ ; -70℃~100℃(+150℃)
10% ~ 98% RH |
| Features |
Temp. & Humi. Constancy |
±0.2℃ ; ±2.5%RH |
| Temp. & Humi. Uniformity |
±0.5℃ ; ± 5 %RH |
| Indication Resolution |
±0.01℃ ; 0.1%RH |
| Heat-up Time |
℃ |
100 150 |
100 150 |
100 150 |
100 150 |
| min |
30 50 |
40 60 |
45 65 |
50 70 |
| Pull-down Time |
℃ |
0 -20 -40 -60 -70 |
0 -20 -40 -60 -70 |
0 -20 -40 -60 -70 |
0 -20 -40 -60 -70 |
| min |
40 50 70 90 100 |
45 50 80 110 130 |
55 60 90 115 140 |
60 70 100 120 150 |
| Material |
Exterior
|
SUS#304 Stainless Steel Pirate |
Interior
|
SUS#304 Stainless Steel Pirate |
Insulation
|
PU & Fiberglass Wool |
| Systems |
Circulation |
Siroco Fan |
| eating |
SUS#304 Stainless Steel High-Speed Heater |
| Humidifying |
Surface Evaporating System |
| Cooling |
Airtight Compressor + Evaporator Fins + Air-Cooling Condenser |
| Dehumidifying |
ADP Critical Dew Point Cooling / Dehumidifying Method |
| Controller |
Digital Electronic Indictors + S.S.R. With PID Automatic Calculation Capability |
| Other Components |
Vacuum Glass Inspection Window, Cable Port(
ψ
60mm),Control Status Indicator Light, Chamber lamp, E×periment Separation Shelves (Freely Adjustable 2Pcs) |
| Safety Devices |
Overheating Prevention Circuit-breaker, Compressor Overload Protection, Control System Overload Protection, Humidifying System Over heading Drying Out Prevention, Breakdown Indicator Light |
| Power Source [K.W.] |
AC 1
ψ
220V; 3
ψ
220/380V 60/50Hz |
| 3 4 6 6 6 |
3.5 5.5 6.5 8.0 8.5 |
4.5 6.0 7.5 9.5 9.5 |
5.5 9 10 10.5 10.5 |